{"product_id":"sungrow-sh15t-sh20t-sh25t-three-phase-hybrid-inverter","title":"Sungrow SH15T \/ SH20T \/ SH25T Three Phase Hybrid Inverter","description":"\u003cp\u003eThe Sungrow SH-T range is a high-performance three phase hybrid inverter platform designed for larger residential properties and high-energy solar and battery installations.\u003c\/p\u003e\n\u003cp\u003eAvailable in 15kW, 20kW and 25kW models, the range combines high-capacity solar input, three independent MPPTs, high-voltage battery compatibility, 50A fast battery charging and discharging, whole-home backup and 100% unbalanced output capability.\u003c\/p\u003e\n\u003cp\u003eThe SH15T, SH20T and SH25T share the same core hybrid platform, allowing customers to select the inverter size that best matches their solar array, battery system and household energy requirements.\u003c\/p\u003e\n\u003ch2\u003eChoose Your Size\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth align=\"right\"\u003eRated Output\u003c\/th\u003e\n\u003cth align=\"right\"\u003eMax PV Input\u003c\/th\u003e\n\u003cth align=\"right\"\u003eBattery Charge \/ Discharge Power\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePeak Backup\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSH15T\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kWp\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kW \/ 15kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e25.5kVA \/ 10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSH20T\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40kWp\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kW \/ 20kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e32kVA \/ 10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSH25T\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e25kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e50kWp\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kW \/ 25kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e36.5kVA \/ 10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHigh-Power Three Phase Hybrid Inverter\u003c\/h2\u003e\n\u003cp\u003eThe Sungrow SH-T range combines solar generation, battery storage and backup functionality within a single three-phase inverter.\u003c\/p\u003e\n\u003cp\u003eChoose from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSH15T – 15,000W rated AC output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH20T – 20,000W rated AC output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH25T – 25,000W rated AC output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll three models support three-phase operation at 220\/380V, 230\/400V or 240\/415V.\u003c\/p\u003e\n\u003ch2\u003eUp to 50kW Solar PV Input\u003c\/h2\u003e\n\u003cp\u003eThe SH-T series provides substantial PV input capacity, making it suitable for large rooftop solar systems.\u003c\/p\u003e\n\u003cp\u003eMaximum PV input varies by model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSH15T – up to 30,000Wp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH20T – up to 40,000Wp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH25T – up to 50,000Wp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe range also supports a maximum PV input voltage of 1,000V, with an MPPT operating range of 150–950V and 180V startup voltage.\u003c\/p\u003e\n\u003ch2\u003e3 Independent MPPTs\u003c\/h2\u003e\n\u003cp\u003eThe SH15T, SH20T and SH25T feature three independent MPPT trackers, providing greater flexibility when designing large solar arrays across multiple roof orientations.\u003c\/p\u003e\n\u003cp\u003ePV configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e3 independent MPPTs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 PV strings in total\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 \/ 2 \/ 1 string configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 80A total PV input current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32A \/ 32A \/ 16A MPPT input current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 100A total DC short-circuit current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000V maximum PV voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e150–950V MPPT operating range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHigh-Voltage Battery Ready\u003c\/h2\u003e\n\u003cp\u003eThe SH-T range supports compatible high-voltage lithium-ion battery systems with a wide 100–700V battery operating range.\u003c\/p\u003e\n\u003cp\u003eBattery performance includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e100–700V battery voltage range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50A maximum charge current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50A maximum discharge current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 30kW battery charging power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaximum battery discharge power varies according to inverter size:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSH15T – up to 15kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH20T – up to 20kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH25T – up to 25kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual maximum battery current depends on the connected battery.\u003c\/p\u003e\n\u003ch2\u003eWhole-Home Backup\u003c\/h2\u003e\n\u003cp\u003eThe SH-T range incorporates a built-in 63A bypass for whole-home backup applications.\u003c\/p\u003e\n\u003cp\u003eDuring a grid outage, the inverter can transition to backup operation in less than 10 milliseconds, helping maintain power to connected backup loads.\u003c\/p\u003e\n\u003cp\u003eBackup capability scales with the selected inverter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSH15T – 15kW rated backup output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH20T – 20kW rated backup output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH25T – 25kW rated backup output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003ePowerful Peak Backup Output\u003c\/h2\u003e\n\u003cp\u003eThe SH-T range provides substantial short-duration peak power when sufficient PV and battery power are available.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSH15T – up to 25.5kVA for 10 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH20T – up to 32kVA for 10 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH25T – up to 36.5kVA for 10 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis additional short-duration capacity can help accommodate equipment and appliances with high startup power requirements.\u003c\/p\u003e\n\u003ch2\u003e100% Unbalanced Output Support\u003c\/h2\u003e\n\u003cp\u003eThe SH-T range supports 100% unbalanced output in both on-grid and backup modes.\u003c\/p\u003e\n\u003cp\u003eThis is particularly useful for three-phase properties where household loads are not evenly distributed across each phase.\u003c\/p\u003e\n\u003ch2\u003eHigh Efficiency\u003c\/h2\u003e\n\u003cp\u003eThe SH-T platform delivers high conversion efficiency across all three models.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSH15T – 98.1% maximum \/ 97.6% European efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH20T – 98.2% maximum \/ 97.8% European efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSH25T – 98.2% maximum \/ 97.8% European efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSmart Connectivity\u003c\/h2\u003e\n\u003cp\u003eThe SH-T range provides multiple communication interfaces for system monitoring, battery communication and energy management.\u003c\/p\u003e\n\u003cp\u003eConnectivity includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWLAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4 digital inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 digital outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDRM0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBuilt-In Safety \u0026amp; Protection\u003c\/h2\u003e\n\u003cp\u003eSungrow integrates multiple protection functions into the SH-T platform.\u003c\/p\u003e\n\u003cp\u003eThese include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePrecise AFCI support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrid monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC reverse-polarity protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeakage-current protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated solar DC switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Type II surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Type II surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePID Zero\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery reverse-polarity protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eBuilt for Australian Installations\u003c\/h2\u003e\n\u003cp\u003eThe SH15T, SH20T and SH25T feature an IP65 enclosure with C5 corrosion resistance, making the platform suitable for indoor or outdoor installation.\u003c\/p\u003e\n\u003cp\u003eGeneral specifications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIP65 \/ C5 protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-25°C to +60°C operating temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–100% allowable relative humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum operating altitude of 2,000m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWall-mounted installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlug \u0026amp; Play connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAS\/NZS 4777.2:2020 listed compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable in 15kW, 20kW and 25kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree phase hybrid solar and battery inverter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 50kWp PV input depending on model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000V maximum PV input voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3 independent MPPTs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 PV strings with 2 \/ 2 \/ 1 configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 80A total PV input current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100–700V high-voltage battery range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50A fast battery charge and discharge current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 30kW battery charging power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 25kW battery discharge power depending on model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in 63A whole-home backup bypass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLess than 10ms backup switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 36.5kVA peak backup output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100% unbalanced output support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 98.2% maximum efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecise AFCI support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePID Zero\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC and DC Type II surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWLAN and Ethernet connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS485 and CAN communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP65 \/ C5 protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlug \u0026amp; Play installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAS\/NZS 4777.2:2020 listed compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSH15T\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSH20T\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSH25T\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eThree Phase\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eThree Phase\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Output\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e25kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Input\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kWp\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40kWp\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e50kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Voltage\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1,000V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1,000V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPTs\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Strings\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 (2\/2\/1)\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 (2\/2\/1)\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 (2\/2\/1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100–700V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100–700V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100–700V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Battery Current\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e50A \/ 50A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e50A \/ 50A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e50A \/ 50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Battery Charge Power\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Battery Discharge Power\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e25kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Off-Grid Output\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20kW\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e25kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Backup Output\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e25.5kVA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e32kVA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e36.5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Peak Duration\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 sec\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 sec\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Switching\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u0026lt;10ms\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u0026lt;10ms\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u0026lt;10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Efficiency\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e98.1%\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e98.2%\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e98.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eIP65 \/ C5\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eIP65 \/ C5\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eIP65 \/ C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e620 × 480 × 245mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e620 × 480 × 245mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e620 × 480 × 245mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e38kg\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40kg\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe supplied datasheet shows the SH15T uses natural convection cooling with typical noise of 35dB(A), while the SH20T and SH25T use fan cooling with typical noise of 50dB(A).\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the Sungrow SH-T Range?\u003c\/h2\u003e\n\u003cp\u003eThe Sungrow SH15T, SH20T and SH25T provide a scalable three-phase hybrid solution for larger solar and battery installations.\u003c\/p\u003e\n\u003cp\u003eWith up to 50kW of PV input, three independent MPPTs, high-voltage battery support, 50A fast battery charging and discharging, 100% unbalanced output and whole-home backup, customers can select the inverter capacity that best matches their property while remaining on the same Sungrow hybrid platform.\u003c\/p\u003e","brand":"Sungrow","offers":[{"title":"Sungrow SH15T - 15KW","offer_id":55125309456663,"sku":null,"price":4798.0,"currency_code":"AUD","in_stock":true},{"title":"Sungrow SH20T -20KW","offer_id":55125309489431,"sku":null,"price":4988.0,"currency_code":"AUD","in_stock":true},{"title":"Sungrow SH25T -25KW","offer_id":55125309522199,"sku":null,"price":7489.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/9365\/9415\/files\/SungrowSH20TThreePhaseHybridInverter.avif?v=1788620761","url":"https:\/\/solarbatterysupermarket.com.au\/products\/sungrow-sh15t-sh20t-sh25t-three-phase-hybrid-inverter","provider":"Solar Battery Supermarket","version":"1.0","type":"link"}